BANDON successfully implemented the heating
renovation of the First City Community in Baoding, Hebei Province, which not
only verified BANDON's leading position in the field of heating technology, but
also reflected the community's firm pursuit of the concept of green and
low-carbon life. Through the implementation of this project, BANDON's heat pump
technology will bring a more comfortable and environmentally friendly living
environment to the First City Community, and also contribute to promoting the green
development of society.
1. Project Overview
The First City Community is located in the
core area of Wangdu County, Baoding City, Hebei Province, with a total
construction area of 320,000 square meters. It is the largest single project of all-DC
inverter high-power commercial units in the country so far. The
region belongs to the mid-warm temperate continental monsoon climate with four
distinct seasons. The average winter temperature is -4.3℃, and the extreme minimum
temperature can reach -15℃. The average annual precipitation is 498 mm, the frost-free period
is between 165 and 210 days, and the freezing period is as long as 4 months,
which lasts for a long time.
Under such climatic conditions, the indoor
temperature of the community residents is set between 20 and 22 degrees
Celsius, requiring the heating system to be equipped with an intelligent
automatic control system to accurately adjust the temperature to ensure that
every resident can enjoy a comfortable living environment. The application of
BANDON's technology not only improves the heating efficiency, but also reflects
the community's firm pursuit of the concept of green and low-carbon life,
providing residents with a warm, comfortable and environmentally friendly
living space.
2. Transformation Background
Guided by the concept of environmental
protection, the First City community decided to abandon the traditional
water-source heating method and adopt the more green and energy-saving BANDON
heating system. This change is a positive response to the government's call for
protecting natural resources, aiming to reduce resource consumption and
environmental damage, while improving the quality of life of residents.
This decision of the community has been
widely supported by residents. They not only agree with the environmental value
of this green heating method, but are also willing to actively participate in
this renovation project and jointly promote the community towards green,
low-carbon and sustainable development. The participation and support of
residents is the key to achieving this goal, and also demonstrates their common
vision and responsibility for building a more comfortable and livable
environment.
3. Equipment Selection
In order to meet the diverse heating needs
of residents in the First City community, BANDON has carefully developed a set
of efficient and energy-saving heating solutions, installing 71 pcs of
80-horsepower ultra-low temperature high-power commercial inverter heat pump
units, equipped with floor heating terminal systems, which can cover the
heating area of 320,000 square meters in the community.
The implementation of this system will not
only greatly improve heating efficiency and reduce energy consumption, but also
provide residents with a greener, more efficient and comfortable living
environment.
4. Equipment Installation
In the centralized heating renovation
project of the First City Community, BANDON Company comprehensively considered
the geographical location, terrain characteristics, equipment selection and
system design of the community, carefully planned the construction plan, and
decided to build a 4-meter-high elevated platform on the open space next to the
community for unit installation. This design is not only convenient for
construction, but also can optimize the unit arrangement and operation
strategy, ensuring that the unit can effectively ventilate and heat during
operation, avoiding the cold island effect, thereby ensuring the safe, stable
and efficient operation of the heating system.
In view of the different heights of the
community floors and the differences in indoor load requirements, the BANDON
design team adopted a partitioned modular layout to divide the heat pump unit
system into three independently operated areas: high, medium and low. This
design ensures that each unit does not interfere with each other during
operation, effectively ensuring the stability and continuity of heating.
Through this intelligent partition layout, not only the overall heating effect
is improved, but also it ensures that residents on each floor can enjoy a
comfortable and pleasant living environment.
5. Operation
With its excellent stability and
reliability, the BANDON heat pump unit can still ensure that the heating needs
of community residents are met in severe cold weather. The unit can not only
maintain the stability of the heating effect, but also effectively improve the
comfort of the indoor environment. Through the built-in intelligent control
system, the unit can monitor and analyze various key operating parameters in
real time, identify and deal with any potential problems in a timely manner,
thereby ensuring the stability and safety of the system.
In addition, this intelligent control
system can also accurately control the indoor temperature to meet the
personalized temperature needs of different residents and ensure that the
heating effect is always in the best state. Overall, the BANDON heat pump unit
has excellent operating performance and provides a reliable and efficient
winter heating solution for community residents.